Engineering Questions with Answers - Multiple Choice Questions

Separation Processes MCQ’s – Newton-Raphson Method

1 - Question

The Newton-Raphson method of finding roots of nonlinear equations falls under the category of which method?
a) Bracketing
b) Random
c) Open
d) Graphical
View Answer Answer: c
Explanation: It is an open method since we have to guess the square root.



2 - Question

What is the formula of finding the square root of R from equation x2- R=0?
a) Xi+1= 0.5(xi + R/xi)
b) Xi+1= 0.5(xi + R/2)
c) Xi= 0.5(xi + R/xi)
d) Xi+1= 0.5(xi + xi)
View Answer Answer: a
Explanation: The formula of finding the square root of R from equation x2– R=0 is Xi+1= 0.5(xi + R/xi).



3 - Question

If broth flow rate is 200kg/hr and solvent flow rate is 300kg/hr and POD is of diameter 1m and length 10m, what is the residence time?
a) 28s
b) 56s
c) 35s
d) 39s
View Answer Answer: a
Explanation: ttme= pi*(D2/4)L/F+S, ttime = 3.14*(1/4)10/500=56s.



4 - Question

If broth flow rate is 600kg/hr and solvent flow rate is 400kg/hr and POD is of diameter 1m and length 5m, what is the residence time?
a) 28s
b) 14s
c) 30s
d) 35s
View Answer Answer: b
Explanation: ttme= pi*(D2/4)L/F+S, ttime = 3.14*(1/4)5/1000=14s.



5 - Question

If broth flow rate is 200kg/hr and solvent flow rate is 300kg/hr and POD is of diameter 1m and length 15m, what is the residence time?
a) 72s
b) 76s
c) 82s
d) 85s
View Answer Answer: a
Explanation: ttme= pi*(D2/4)L/F+S, ttime = 3.14*(1/4)15/500=85s.



6 - Question

If broth flow rate is 200kg/hr and solvent flow rate is 300kg/hr and POD is of diameter 2m and length 5m, what is the residence time?
a) 98s
b) 111ss
c) 113s
d) 119s
View Answer Answer: a
Explanation: ttme= pi*(D2/4)L/F+S, ttime = 3.14*(4/4)5/500=113s.



7 - Question

If broth flow rate is 200kg/hr and solvent flow rate is 300kg/hr and POD is of diameter 1m and length 6m, what is the residence time?
a) 28s
b) 20s
c) 30s
d) 34s
View Answer Answer: d
Explanation: ttme= pi*(D2/4)L/F+S, ttime = 3.14*(1/4)6/500=34s.



8 - Question

If broth flow rate is 200kg/hr and solvent flow rate is 300kg/hr and POD is of diameter 1m and length 7m, what is the residence time?
a) 28s
b) 20s
c) 40s
d) 35s
View Answer Answer: c
Explanation: ttme= pi*(D2/4)L/F+S, ttime = 3.14*(1/4)7/500=40s.



9 - Question

If broth flow rate is 200kg/hr and solvent flow rate is 300kg/hr and POD is of diameter 3m and length 5m, what is the residence time?
a) 200s
b) 250s
c) 230s
d) 254s
View Answer Answer: a
Explanation: ttme= pi*(D2/4)L/F+S, ttime = 3.14*(9/4)5/500=254s.



10 - Question

If broth flow rate is 200kg/hr and solvent flow rate is 500kg/hr and POD is of diameter 1m and length 5m, what is the residence time?
a) 28s
b) 20s
c) 30s
d) 35s
View Answer Answer: b
Explanation: ttme= pi*(D2/4)L/F+S, ttime = 3.14*(1/4)5/700=20s.

Get weekly updates about new MCQs and other posts by joining 18000+ community of active learners